The purpose of this lab is to learn how to create counters and to be able to control when operations
occur at high clock speeds.2 Marking Scheme
This lab, like other labs, is worth 6% of your final grade, but you will be graded out of 8 marks for this
lab, as follows:
• Prelab: 3 marks
• Part I: 1 mark
• Part II: 2 mark
• Part III: 2 marks3 Preparation Before the Lab
You are required to complete Parts I to III of the lab by building and testing circuits in Logisim. Include
your schematics and Logisim files for Parts I to III in your prelab. You must simulate your circuit inside
Logisim, but since the Logisim test vectors only handle combinational circuits, your prelab report will
include a test plan and important test cases (which will be tested in your demo). You should also answer
the questions in the handout that are marked as (PRELAB).You are required to implement and test all of Parts I to III of the lab. You need to demonstrate all parts
to the teaching assistants.4 Part I
Consider the circuit in Figure 1. It is a 4-bit synchronous counter that uses four T-type flip-flops. The
counter increments its value on each positive edge of the clock if the Enable signal is 1 (i.e. high). The
counter is reset to 0 by setting the Clear b signal low, which means that the clear is an active-low
asynchronous clear. (In Logisim, all the input signals are asynchronous active high by default.) You
should implement an 8-bit version of this counter.T Q
Clock Q
T Q
Q
Enable
Clear_b
T Q
Q
T Q
Q
Figure 1: A 4-bit counter.An asynchronous clear means that as soon as the Clear b signal changes (here from 1 to 0 since we
have an active-low signal), irrespective of whether this change happened at the positive clock edge or
not, the T flip-flop should be reset. This is in contrast to the synchronous reset, where the D flip-flop
can only be reset at the positive edge of the clock.For this part, perform the following steps:
1. Draw the schematic for an 8-bit counter using the same structure as shown in Figure 1. (PRELAB)
2. Annotate all Q outputs of your schematic with the bit of the counter (Q7Q6Q5Q4Q3Q2Q1Q0) that
they correspond to (where Q7 is the most significant bit and Q0 is the least significant bit. Label
the inputs according to the diagram in Figure 1. (PRELAB)3. Build the circuit corresponding to your schematic. Your circuit should use the flip-flop module
provided by Logisim, instantiated eight times to create the counter. (PRELAB)Note that for the modules that you are instantiating, it is best if you use the default input and
output from the toolbar. It is recommended that you should name your inputs and outputs in
a way that makes it easy to interpret your simulations (e.g. use input/output names from your
schematic).4. Connect the Q output bits to two seven-segment displays so you can monitor the output values.
(PRELAB)5. Test your modules with Poke( ) to verify its correctness. You will need to reset (clear) all your
flip-flops early in your simulation, to ensure that your circuit starts in a known state. Include
screenshots of simulation output in your prelab. (PRELAB)5 Part II
Another way to specify an counter is by instantiating a register and adding 1 to its value at each iteration.
Adding 1 can be accomplished using the Adder under Arithmetic. The constant value 1 can be found in
Wiring > Constant, and you can set the value and the number of data bits for this constant in Properties
after you click on it.Figure 2: Counter in Logisim
Figure 2 shows an example of a counter in Logisim that counts in hexadecimal from 0 to F. You can
find this counter in Memory > Counter.The counter has the following input signals:
1. An active-high asynchronous clear (R at the top left corner),2. Signals M1 [load] and M2 [count] that perform load and counter enable, where an input of 1 means
loading the value and 0 means start counting3. Signals M3 [up] and M4 [down] (note that they are just one signal) which determine whether to
count up or down.4. Inputs called 2,3,5+/C6 and 2,3,5+/C6 that should be connected to a Clock signal. The value
that to be loaded needs to be connected the bottom left side of the counter and the value within
the counter that is incremented/decremented will be on the bottom right side of the counter.The implementation above is a 4-bit counter, however you can change this in Properties if you wish to
use more bits. In your prelab report, provide the answers to the following questions:
1. The check for the maximum value is not necessary in the example above. Explain why in your
prelab report (PRELAB)2. If you wanted this 4-bit counter to count from 0-9, how would you adjust the circuit above?
(PRELAB)3. In Properties there is a setting called Action On Overflow. Explain how each value for this setting
responds to overflow by experimenting with this setting and describing the results. (PRELAB)In this part of the lab you will design and implement a circuit using counters that successively flashes
the hexadecimal digits 0 through F on a hex display. A two-bit input value to your circuit will be used
to determine the speed of flashing according to the following table:
SW[1] SW[0] Speed
0 0 Full (16 Hz)
0 1 1 Hz
1 0 0.5 Hz
1 1 0.25 HzYou must design a fully synchronous circuit, which means that every flip flop in your circuit should be
clocked by Logisim’s default 16Hz clock signal. If we were operating with the DE1-SOC boards, the
built-in clock would run much faster, at 50 MHz. Logisim provides a slower set of clocks, and we’ll use
the 16Hz during simulation.While you are able to change the rate of the simulation clock in Logisim, for this part we want to assume
that the clock speed is fixed. What we want instead is to create circuitry that takes in the clock and the
two-bit values from SW[1] and SW[0] as inputs. The output would be a new clock signal that is used for
the hex display to make its digits flash at a slower speed.Two modules are required to make this happen:
1. A special kind of counter called a RateDivider which takes in the 16Hz clock signal and outputs
a new clock signal, slowed down to a rate specified by SW[1] and SW[0].2. A second counter called DisplayCounter. This is a hexadecimal counter that is responsible for
counting through the values 0 – F. Recall that an enable signal determines whether a flip flop,
register, or counter will change on an active edge of the clock or not.The output of the RateDivider generates a slower alternating signal, which is then used as the enable
signal of the DisplayCounter module. Every time RateDivider has counted the appropriate number of
clock edges, it generates a high output pulse for one clock cycle. For example, Figure 3 shows a timing
diagram that produces a 1 Hz pulse signal from a 50 MHz clock (the kind used on the DE1-SOC board).The resulting 1 Hz pulse signal would provide the Enable value for the DisplayCounter module.
In your prelab report, calculate how large a counter would be required to count 50 million clock cycles,
as illustrated by Figure 3. How many binary bits would that counter need to represent such a value?
(PRELAB)
3
50 MHz
1.00 Hz
Enable
50 Million Clock Cycles 50 Million Clock CyclesFigure 3: Timing diagram for a 1 Hz enable signalA common way to count a specified number of clock pulses is to parallel load the RateDivider counter
with the appropriate starting value and then count down to zero. For example, if you want to count 50
million clock cycles (as in the above example), simply load the counter with 50 million and subtract one
at each time the clock pulses until the counter reaches 0 (strictly speaking, you would load the value
49,999,999). The counter would then be reloaded to the starting value again.A few more notes about your final circuit:
1. The AND gate on the right side of Figure 2 performs two tasks: it turns on the output Enable
signal once the counter reaches a certain value and it performs a parallel load of a new counter
value (specified by you) on the next clock cycle. This is one way to make the RateDivider counts
a certain number of clock cycles before turning on the enable signal. Using this idea, changing the
frequency of the new clock signal would just involve changing the value you load into the counter.• This counter design in Figure 2 is provided for you and you can use it as a model to build
your counters.• You don’t have to follow this model exactly. As long as you use the counter provided by
Logisim, you can use whatever other circuitry you prefer to implement the RateDivider behaviour. Be creative! We only provide this idea to get you thinking about what your circuit
needs to do.2. DisplayCounter counts 4-bit binary values, incrementing each time its Enable input is 1. When the
counter reaches 1111, the next increment should reset it to 0000. The output of this DisplayCounter
should be directed to a seven-segment display so that the TAs can observe the counter result.• You can use whichever counter you’d prefer for this part, either the one you created in Part I
or Logisim’s built-in counter.For this part of the lab, you need perform the following steps:
1. Draw a schematic of the circuit you wish to build. Mentally step through the usage of this circuit
to ensure that your circuit handles the necessary use cases to the best of your understanding.
(PRELAB)2. Build the circuit that realizes the behaviour described in your schematic. Your main circuit should
have one clock input, one reset input and two external switch inputs (SW[1] and SW[0]) for the
RateDivider. The circuit should have a seven-segment display as output. (PRELAB)HINT: You should name the inputs and outputs of each module in a way that makes it easy to
interpret your simulations (e.g. use input/output names from your schematic).3. Simulate your modules with Poke( ). Choose test cases that make you feel confident about
your counter’s correctness in preparation for you in-lab demo. Make sure to include a few selected
screenshots of these cases when you hand in your prelab. You will also need to think about the
best way to simulate this kind of circuit. For example, how many 16 Hz clock pulses will you need
to simulate to show that the RateDivider is properly outputting a 1 Hz pulse? (PRELAB)(HINT: Sometimes simulating a circuit in its entirety is infeasible. It is therefore important to
identify which are the critical aspects of the circuit you need to simulate to be confident that your
circuit will work. Demonstrating this for a smaller problem can be one valid approach.)4. Label your high-level Logisim design with the appropriate input and output names that would be
used on the DE1-SoC board (e.g. use HEX0 as the seven-segment display from the DisplayCounter
while using switches SW1−0 to control the rate that these hex digits are updated). You will also
need to use additional switches (e.g., the clear signal). (PRELAB)6 Part III
In this part of the lab you are going to design and implement a Morse code encoder.
Morse code uses patterns of short and long pulses to represent a message. Each letter is represented as a
sequence of dots (a short pulse), and dashes (a long pulse). For example, the last 8 letters of the English
alphabet have the following representation:
S • • •
T —
U • • —
V • • • —
W • — —
X — • • —
Y — • — —
Z — — • •Your circuit should take as input one of eight letters of the alphabet (shown in the table above) and
display the Morse code signals for it on an LED (you can find LEDs in Input/Output > LED).To make this happen, you need to create the following:
1. A lookup table (LUT) to store the Morse code sequences for each letter,
2. A shift register to display the Morse signals,
3. A rate divider to set the timing for the shift register.Let us first look into how we will store the Morse code representation for each letter. A ”dot” will cause
the LED to flash for 0.5 seconds while a ”dash” will cause the LED to flash for 1.5 seconds. Since both
of these times are multiples of 0.5 seconds, we will use this to our advantage when representing a Morse
code sequence as a sequence of binary numbers.Each Morse code sequence will be a sequence of 1s and 0s where the 1 indicates when the LED should
turn on and the 0 indicates when the LED will turn off. Let’s assume that each bit corresponds to a
display duration of 0.5 seconds, so a single 1 bit in the sequence will correspond to a ”dot” (the LED
should stay on for 0.5 seconds), while three 1s in a row (i.e., 111) will correspond to a ”dash” (the LED
should stay on for 3 ∗ 0.5 seconds).The sequence will then use 0 values to separate those signals (i.e., the
LED will turn off for 0.5 seconds in between dots and dashes). As a result, the LED could be off either
5
during a pause (e.g., a transition between a Morse dash and a dot), the beginning/end of a transmission,
or if there is no transmission.Using this representation, the Morse code for letter X could be stored as 1110101011100000, assuming
we use 16-bits to represent it (this is not a required length). To implement the LUT, you will need to use
the same approach to fill in the remaining entries in Table 1 with the Morse code binary representation
for the other letters specified above (S to Z). (PRELAB)• Note that each letter will require a different minimal number of bits in this representation. However,
you will need to make sure all the sequences are the same length because they all need to be loaded
into a single shift register to display them on the LED. The shift register will be a fixed length,
therefore the length of your binary sequences below will also need to be a single fixed length.• To figure out what this length will be, you need to figure out the maximum number of bits needed
when representing the Morse code sequences for each of the letters (S to Z). Once you have that,
adjust all of the binary sequences to match that maximum length. For letters that do not require
that maximum number of bits, extend any of the 0 sections of that sequence. Make sure that the
last bit of any Morse code representation is set to 0.Fill in Table 1 below as part of your prelab. You will need to fill in the header of the third column with
the sequence length you decided on. You will also need to pad the sequence for letter X with added
zeroes as needed to match the sequence length you chose. (PRELAB)
Letter Morse Code Pattern Representation (sequence length is bits)
S • • •
T —
U • • —
V • • • —
W • — —
X — • • — 111010101110
Y — • — —
Z — — • •Table 1: Morse Pattern Representation with fixed bit-width (PRELAB)
The LUT will store the binary representation of each Morse code pattern and use a multiplexer to
determine which pattern is sent to the output bits. The LUT will take in a 3-bit input to specify the
letter sequence to display, where 000 denotes the sequence for letter S and 111 denotes the sequence for
letter Z. So if each Morse sequence was 16 bits long, the LUT would have a 3-bit input and a 16-bit
output. This LUT is asychronous, so no clock or reset signals are needed.The next module to consider is the shift register. With the LUT supplying a sequence to display on the
LED, we need a module that can display each bit, one at a time, in order. To do that, use a shift register
and follow these steps:1. Load the sequence from the LUT into the shift register (using the shift register’s parallel load).
Make sure the shift register length is the same as the sequence length from Table 1.2. Shift the sequence by one bit each time the clock goes high.3. Have the bit that is shifted out of the register displayed on the LED.
The third and final module that you will need is the rate divider, which will supply the shift register
with the appropriate clock signal (one that goes high every 0.5 seconds).A high-level block diagram of the circuit you are building is shown in Figure 4. Note that various
details/connections are not shown there.To summarize, once the user presses a button that starts the LED display process you need to load a
shift register with the appropriate pattern (for the letter specified by a 3-bit input) and display the Morse
6
En
To LEDR[0]
Figure 4: Block diagram of the Morse code circuit
code from that pattern on the LED. Note that you should not display a given letter in a loop (i.e., you
should only re-display the same letter if the user presses the start button again).In the event that you have not completed part II of the lab (i.e. you have not been able to implement
the 0.5 second enable signal), manually clock your shift register using a switch input signal. This will
help you to get partial marks.Complete the lab by performing the following steps:
1. Use Table 1 to determine your codes and bit-width. (PRELAB)
2. Design your circuit by first drawing a schematic of the circuit. Think and work through your
schematic to make sure that it will work according to your understanding. You can use Figure 4
as your starting point. You should include the schematic in your prelab. (PRELAB)3. Build the circuit in Logisim that realizes the behaviour described in your schematic. (PRELAB)
HINT: You should name your inputs and outputs in a way that makes it easy to interpret your
simulations (e.g. use input/output names from your schematic).4. Simulate your LUT with test vectors and your shifter module with Poke( ). Choose test cases
that make you feel confident about your LUT and shifter’s correctness in preparation for your
in-lab demo. You are strongly encouraged to complete this step before performing your lab demo.
Document the test cases that you considered (especially the corner cases) in your prelab report
and include screenshots of the most interesting cases. (PRELAB)5. Label the inputs and outputs of your Logisim design to correspond to the inputs and outputs on
the DE1-SoC board. The following table summarizes the inputs and outputs that you will use:
(PRELAB)
Input/Output Purpose
SW[2:0] Choose one of the 8 letters S to Z
KEY[1] Start diplaying Morse code for chosen letter
KEY[0] Asynchronous reset
LEDR[0] Output used to display Morse code
5, and, Clocks, Counters, Lab, Solved:CSC258, –
[SOLVED] :csc258 – lab 5 clocks and counters
$25
File Name: :csc258_–_lab_5_clocks_and_counters.zip
File Size: 348.54 KB
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.